All systems

6,000 W · 5,376 Wh

Professional 6 kW output with voltage-dependent specifications.

The EP6000iLS combines 5,376 Wh LiFePO4 storage with up to 6,000 W rated output at 120–240 V and documented AC and PV charging options.

6.000 W5,376 Wh · professional
EP6000iLS portable power stationDRIVELONG
EU SYSTEM

KEY POINTS

Designed for an energy profile that goes beyond the standard.

01

Voltage-dependent rated power

6,000 W at 120–240 V, 5,500 W at 110 V and 5,000 W at 100 V.

02

Protection & transfer

Unit IP53, battery pack IP66 and transfer time ≤10 ms.

03

AC & PV charging

Dual AC input and PV charging are configuration-dependent; optional charging equipment is clearly separated.

04

EP6000B expansion

EP6000B extra batteries are sold separately; the source states up to 31 units and a total of 172 kWh.

TECHNICAL SPECIFICATIONS

Verified values for each system.

Download technical datasheet
Storage capacity
5.376 Wh
Rated output
6,000 W / VA (120–240 V) · 5,500 W / VA (110 V) · 5,000 W / VA (100 V)
Peak output
12,000 W / VA (120–240 V) · 11,000 W / VA (110 V) · 10,000 W / VA (100 V)
Battery
LiFePO₄ · 5,376 Wh · 105 Ah (51.2 V) · 5,000 cycles to ≥80% capacity
Protection rating
Unit IP53 · battery pack IP66
Transfer time
≤10 ms
Solar input
Single-phase PV: 80–450 VDC, 27 A max., up to 5,500 W; split-phase PV: 12–150 VDC, 30 A max., up to 3,000 W
Charging options
AC: 3,600/5,500 W single-phase or 1,700/5,500 W split-phase. Driving charger and DC charger are optional
AC output
Pure sine wave · THD <3% · 50/60 Hz · single-phase 220/230/240 V or split-phase 100/200, 110/220 or 120/240 V
DC & USB outputs
Cigarette port 12 V/10 A · optional USB 5 V/3.1 A, QC3.0 and USB-C PD60W
Parallel & battery expansion
EP6000B: 5,376 Wh (51.2 V); up to 31 units (source: total 172 kWh). Optional DC Quick Charger for EP6000B
Dimensions
610 × 560 × 500 mm
Weight
70 kg

PRACTICAL RUNTIME

How long can this system run as an indication?

Add the equipment you intend to use. The calculator totals the output and uses your simultaneous-use factor plus a 15% practical energy reserve.

Calculate with system

Select the BP3600 or BP2400 directly. Your equipment list remains when you switch.

Equipment list

Enter each device’s rated power draw in watts.

Common starting values
Indicative values: always check your own equipment’s rating plate and any start-up peak.

Add at least one device with an output to see an indication.

Indication only, not a guarantee. Actual runtime depends on load profile, temperature, state of charge, connections and charging opportunities.

Discuss this load

APPLICATIONS

Built for the reality on site.

Every installation starts with the work that must keep running. That is why we look beyond wattage alone.

Discuss your application
01Installation
02Rental
03Camper & off-grid
04Landscaping
05Mobile workshop

Power planning. Review peak load, connections and runtime in advance.

Charging strategy. Combine grid charging, solar and mobile charging options where appropriate.

Continuity. Choose a setup that fits your critical power requirement.